IRIS Instruments
HomeLogin

Syscal R1 Plus

Syscal Pro

The SYSCAL R1 Plus resistivity meter is specifically designed for medium-depth exploration. It combines a power source, transmitter up to a 200W or 800Vpp output voltage, and a 2 channels receiver in a single unit; its compactness makes it an effective tool for intensive resistivity surveys.

The measurement is fully automatic, controlled by a microprocessor: automatic self-potential correction, automatic ranging, digital stacking for signal enhancement, error display in case of procedure troubles. The internal memory can store full information on intensity, voltage, resistivity, IP Chargeability, geometrical parameters and station number. A serial link permits transfer of the data to a microcomputer for plotting and interpretation of the data.
It can be used for civil engineering, groundwater and environmental projects, to solve problems such as depth-to-bedrock determination, localization of weathered bedrock. Its power makes it adapted to detect fault in fractured bedrock aquifers and to explore groundwater aquifers (depth and thickness).

View Syscal R1 Plus switch ...

Software

Download
pdf

Prosys II

Resistivity data management
Download
pdf

ProsysView

Android App to visualize data from Syscal pro / Elrec
available on Google Play store
Download
pdf

Electre Pro

Sequence management for Multi-Electrode units

Characteristics

Transmitter

Voltage: 

0 - 1200 Vpp

Current: 

0 - 2500 mA

Power: 

Auto controled Internal 200W DC/DC converter

Battery: 

Internal or external 12 V battery

Receiver

Pulse duration: 

250ms, 500ms, 1s, 2s, 4s, or 8s

Channels: 

2 channels

Input Impedance: 

100 MOhms

Input Voltage: 

15V, automatic gain, input protection 1000V 

1 µV / 0.2%

Resolution / Accuracy: 

Readings: 

Resistivity, Self potentiel, Induced polarisation ( Up to 20 windows), and Quality control

Noise Rejection: 

power line rejection, SP linear drift correction.

Storage: 

44800 readings, stored on solid state memory

Dimensions

( L x W x H)

31x23x21cm Fiber glass casing, weather proof

weight: 

9.8Kg with internal RX, TX batteries

Operating Temp.: 

-20 to +70°C

Documentation

pdf
Datasheet
pdf
Checklist
Principles of geophysical methods for groundwater investigations
pdf
Master curves for schlumberger sounding interpretation
pdf
Step-by-step operation of SYSCAL resistivitymeters
pdf

IRIS Instruments
1 Av. Buffon 45100 Orléans, France
Copyright © IRIS Instruments. All Rights reserved.